Browsing by Author "Claridge, D. E."
Now showing items 1-20 of 179
-
Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2001)The occupancy factor is often underestimated in inverse modeling of building energy use, or accounted for by grouping the daily data in occupied and unoccupied groups which are modeled separately. For instance, in institutional ...
-
Liu, M.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1996)Heating penalty is expected when economizers are applied to dual-duct air handling systems. The heating penalty can even be higher than the cooling savings when the hot air flow is higher than the cold air flow. To avoid ...
-
Zhou, J.; Wei, G.; Turner, W. D.; Claridge, D. E. (Energy Systems Laboratory, 2008-12)Air-side economizer is broadly adopted in building HVAC design and operations. When the system is properly designed and the control sequence is properly implemented, air-side economizer provides significant energy savings. ...
-
Zhou, J.; Wei, G.; Turner, W. D.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu), 2008-10)Air-side economizer is broadly adopted in building HVAC design and operations. When the system is properly designed and the control sequence is properly implemented, air-side economizer provides significant energy savings. ...
-
Christman, K. D.; Haberl, J. S.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu), 2009-11)This analysis was conducted to identify the energy cost savings from retrofitting Texas buildings with air-to-air ERV (Energy Recovery Ventilator) systems. This analysis applied ERV and psychrometric equations in a bin-type ...
-
Chen, L.; Kissock, J. K.; Haberl, J. S.; Heneghan, T.; Ruch, D.; O'Neal, D. L.; Katipamula, S.; Hinchey, S.; Wang, J.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1990)The analysis effort during the first year of the Texas LoanSTAR Monitoring and Analysis Program has emphasized selection and development of baseline analysis techniques to cover the range of buildings expected in the ...
-
Claridge, D. E.; Liu, J.; Baltazar, J. C. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2010)At the beginning of an existing building commissioning (EBCx)/energy retrofit project, some form of screening is usually applied to determine whether there is sufficient potential for savings to justify a formal EBCx ...
-
Haberl, J. S.; Claridge, D. E.; Culp, C. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2005)
-
Haberl, J. S.; Reeves, G.; Gillespie, K.; Claridge, D. E.; Cowan, J.; Culp, C.; Frazell, W.; Heinemeier, K.; Kromer, S.; Kummer, J.; Mazzucchi, R.; Reddy, A.; Schiller, S.; Sud, I.; Wolpert, J.; Wutka, T. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2001)ASHRAE has recently completed the development of Guideline 14 to fill a need for a standard set of energy (and demand) savings calculation procedures. Guideline 14 is intended to be a guideline that provides a minimum ...
-
Haberl, J. S.; Baltazar, J. C.; Sung, Y. H.; Claridge, D. E.; Turner, W. D. (2002-12)This report presents electricity, natural gas and cooling baselines for the thermal plant, buildings located in the 87000 block, and the III Corp building at Ft. Hood. A baseline analysis is also presented for the natural ...
-
Haberl, J. S.; Baltazar-Cervantes, J. C.; Liu, Z.; Claridge, D. E.; Turner, W. D. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2003)This report presents electricity, natural gas and cooling baselines for the thermal plant, buildings located in the 87000 block, III Corp building and other buildings that were determined to be part of the ESPC project at ...
-
Katipamula, S.; Reddy, T. A.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1994)An empirical or regression modeling approach is simple to develop and easy to use compared to use of detailed hourly simulations. Therefore, regression analysis has become a widely used tool in the determination of annual ...
-
Yazdani, B.; Haberl, J. S.; Culp, C.; Turner, W. D.; Claridge, D. E.; Myers, M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)The Rebuild America program is network of community-based partnerships that rebuilds communities by promoting the efficient use of energy. Rebuild America is coordinated at the national level by sponsorship through the ...
-
Bynum, J.; Jones, A.; Claridge, D. E. (Energy Systems Laboratory, 2011-10)Most often commissioning of existing buildings seeks to reduce a building’s energy consumption by implementation of operational changes via the existing equipment. In contrast, large scale capital retrofits seek to make ...
-
Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)
-
Liu, Y.; Reddy, T. A.; Katipamula, S.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1992)As part of the LoanSTAR program, Stroman High School in Victoria Texas underwent two retrofits: a) an absorption chiller was changed to an electric vapor compression chiller, and b) an EMCS system was installed after ...
-
Liu, Y.; Reddy, T. A.; Katipamula, S.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1992)As part of the LoanSTAR program, Victoria High School in Victoria, Texas underwent two retrofits: a) an absorption chiller was changed to an electric vapor compression chiller, and b) an EMCS system was installed after ...
-
Xu, C.; Chen, Q.; Claridge, D. E.; Turner, W. D.; Deng, S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2005)
-
Claridge, D. E.; Schrock, D. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1988)The City of College Station, Texas adopted a new residential Energy Compliance Code in January, 1988. The code, which strengthens compliance requirements in several areas, has received broadly based support and acceptance ...
-
Claridge, D. E.; Gong, X. (2008-04)A detailed study has been conducted of the performance of several innovative aspects of the Intelligent Workplace (IW) at Carnegie Mellon University, a low energy consumption building that uses radiant heating, cooling and ...